If a whole sequence has quality less than the threshold or the length of the output sequence less than the minimum length threshold then the sequence is skipped.
...
Elemet type: SequenceQualityTrim
Parameters
Parameter | Description | Default value | Parameter in Workflow File | Type |
---|---|---|---|---|
Trimming quality threshold | Quality threshold for trimming. | 30 | qual-id | numeric |
Min length | Too short reads are discarded by the filter. | 0 | len-id | numeric |
Trim both ends | Trim both ends of a read or not. Usually, you need to set True for Sanger sequencing and False for NGS | True |
qual-id
numeric
len-id
numeric
Type: SequenceQualityTrim
both- |
ends | boolean |
Input/Output Ports
The element has 1 input port.
Name in GUI: Input data
Name in Workflow File: in-sequence
Slots:
Slot In GUI | Slot in Workflow File | Type |
---|---|---|
Sequence | sequence | sequence |
And 1 output port:
Name in GUI: Output data
Name in Workflow File: out-sequence
Slots:
Slot In GUI | Slot in Workflow File | Type |
---|---|---|
Sequence | sequence | sequence |